Housed
Timers |
|
| |
Housing: |
SABS with
11-Pin Plug-In Base |
Protection: |
1P30 |
Size: |
80x80x35mm
(Excluding pins) |
Supply
Voltage: |
12-24-48-110-220-380-525
VAC 12-24-48-110-220 VDC
Scale Accuracy: 5% |
Repeatability: |
1% |
Relay
Rating: |
10 Amp
Single change over at 220VAC
5 Amp Double change over at 220VAC |
Slandered
Time Ranges: |
1 - 3 -10
- 30 - 60 - 90 -180 - 300 - 600 sec
30 - 60 -180 min |
Range
Accuracy |
+/- 5% |
Voltage
Limits |
+/- 15%
specified voltage |
Temperature
Limits |
-15 deg
C + 55 deg C |
Function |
Code |
Function
Drawing |
Connection
Diagram |
ON-AFTER
DELAY TIMER |
PDO |

|

|
Operation
|
PDO
- Delay On (Power-Up) On Power-up, Red LED is ON &
Relay (Green LED) is OFF. When set time has elapsed;
the Relay will energize (ON). The unit will remain in
this state until power is removed. |
Function |
Code |
Function
Drawing |
Connection
Diagram |
EQUAL
REPEATING TIMER |
PPE |

|

|
Operation
|
PPE
- Equal Repeating (On/Off Cycle)
1. No Link On Power-up, Red & Green LED ON (Power
& Relay is ON). When set time has elapsed, Relay
will release (OFF).
After set time has elapsed again, Relay will energize
(ON).
2. Link 6-7 On Power-up, Red LED is ON & Relay (Green
LED) is OFF. When set time has elapsed, Relay will energize
(ON). After set time has elapsed again, Relay will release
(OFF). |
Function |
Code |
Function
Drawing |
Connection
Diagram |
UNEQUAL
REPEATING TIMER |
PPI |

|

|
Operation
|
PPI
- Unequal Repeating (On/Off Cycle)
On Power-up, Relay (Yellow LED) is ON. When OFF Time
has elapsed, Relay will release. When completing ON
Time (independently selected to OFF Time), the Relay
will energize. This cycle will continue until power
is removed. Note. If power is removed the relay will
go to OFF position. |
Function |
Code |
Function
Drawing |
Connection
Diagram |
ON-DURING
DELAY NO POWER |
PDFN |

|

|
Operation
|
PDFN
- Delay Off No-Power On Power-up, Red LED is On (Power
& Relay is ON). On the removal of power; the pre-set
time begins. When this time has elapsed, the Relay will
release (Red LED OFF). The unit will remain in this
state until power is reapplied. Max time 5 mm. |
|
|
 |
|
 |
|
|