6 Digit Elapsed Timer

  DIG-NELP
     
You can download a full spec sheet for this section. This spec sheet is in adobe's acrobat reader format. If you do not have this software please click on the link below "download acrobat reader".
     
 

• Crystal controlled Elapsed time
• Start, Stop, Reset
• NPN Input
• 12V DC Supply for proximity switches
• Large LED Display
• Standard 96 X 48 X 75mm deep case
• Time saved on power failure
• Maximum reading is 99Hrs99Mins 59 seconds
• Minimum time is 99Mins 99seconds and .01 of a second counting

 

For other panel meter products select your preference in the menu on the right >

 

DIG-NELP

The Microsolve elapsed timer uses the latest Flash CMOS microprocessor technology with crystal control for timing operation. This makes the unit reliable and compact and simple to use.

 Single Phase Volt / Amp Meters

The unit via an internal connector, and a combination of display digits, can be programmed to either time in seconds or 100th of a second. At time of ordering, specify the range, alternatively purchase the 2 different front display glass. The unit in reality has an internal timer of 8 digits, by selecting the display window, the elapsed timer can be easily programmed for the required function.

 

All inputs to the timer are active when taken to ground, so that connections to proximity switches and mechanical switches is simple. This also allows proximity switches to work off other voltages above 12V DC to interface to the timer. This method of input detection lends itself immune to electrical noise, since noise generated by electrical devices switching on or off always create positive going spikes. Input protection against spurious spikes and noise has been eliminated by field proven design. The Start input triggers the timer the moment a contact is made, and will not degrade the counting process if the contact remains in a closed position. The unit will only respond to a stop input, if the start input is released. This interfaces easily into timing of events on electrical equipment.

 

Timing during power failure is not available on this model.

 
 

Specifications

Aux Supply

12V, 24V, 48V, 110V, 230V, 400V, 525V +/- 20% of nominal supply.

Power Consumption

2VA

Input

NPN or potential free contact

Clock accuracy

10 PPM per degree centigrade

Reset Input is master and will over ride all other inputs


Save timer count on power fail is user selectable

 

Output supply

12V D.C. @ 50mAmp

Operating Temperature

–5 to 60 degrees centigrade

Relative humidity

Maximum 75% at 40 degrees Celsius


 
 
  View All
  DPM-3AMA
  1/3 phase volt/amp
  DPM-VISA
  DPM-VIAA
  Three phase amp
  DPM-CDC 3.5 digit
  DPA-XSPA 3/4 Digit Amps
  DPA-XSPT 3/4 Digit Temp
 
DPA-XSPV 3/4 Digit Volt
 
DIG-NTOT 6 Dig Counter
 
DIG-NELP 6 Dig Timer
 
DIG-NRTC 6 Dig real Timer
  Housed Timers
  PDO
  PPE
  PPI
  PDFN
  Tel-A-Fare
  View All
  PFFC
  PFF1
  PFF2
  PFF3
  PFF4
  PWM
  PFR
  PFRP
  View All
  PLLP
  PVC
  PSPU1
  PSPU3
  PFP
  PCWD
  PPST
  PSA
  View All
  2 Digit Temp Controller
  3 Digit Temp Controller
  3 Digit H/Temp Controller
  3 Digit Thermo Control
  3 Digit Thermo Indicator
  2 Digit Indicator
  3 Digit Indicator
  2 Digit Temp Alarm
  Digital Panel Timer
Designed & maintained by
world-portalz.com
Site Designed and Maintained by  World-portalz.com