3/4 Digit Pre-settable Volts Indicator

  DPM-XSPV
     
You can download a full spec sheet for this section. This spec sheet is in adobe's acrobat reader format. If you do not have this software please click on the link below "download acrobat reader".
     
 
 

• True RMS on AC inputs
• Direct Voltage measurement
• AC or DC models available
• 3 or 4 digit display
• Display set point
• Digital potentiometer
• Set maximum set point adjustment
• Set point adjustment must be intentional
• +/3 digits accuracy
• 16Amp SPDT relay output
• Span and decimal point selectable

 

For other panel meter products select your preference in the menu on the right >

 

DPM-XSPV

The Microsolve Set Point Instrument covers all the requirements that you may have in a process control environment. This state of the art instrument uses a 10 bit analogue to digital microprocessor technology to bring you an inexpensive yet reliable and accurate instrument. Designed using the minimum of components for long term reliability, the measuring algorithm takes approximately 200 readings per second, yet the display is updated in such a manner that the reading is comfortable on the eye.

 Single Phase Volt / Amp Meters

Setting of the instrument requires that the user press the panel set point switch to ensure that the set point is not changed unintentionally. Since the setting potentiometer is a digital potentiometer, the position of the potentiometer does not affect the reading until it is rotated.

 

Span adjustment is a simple procedure. Remove the front bezel, and with an insulated pliers select the span adjustment jumper position. Please note that the instrument points are at the measured value potential, and steps must be taken not to touch any points of the instrument board, as a fatal shock may occur Then using the digital potentiometer, set the span according to the input. The same procedure is used to set the maximum range of the set point. This option is ideal as a safety limit, to ensure that operators cannot set a higher value than the limit, ensuring that damage is avoided on equipment being monitored.

 

 

Specifications

Voltage measurement range

A.C. minimum 5V maximum 600V
D.C. minimum 5V maximum 600V
Lower voltages require amplification and would use the current detection card.

Supply input

110V, 230V, 400V, 525V +/- 20% of nominal supply.

Display

LED display for process value and set value.

Accuracy

+/- 3 digits across measurement range

Operating Temperature

–5 to 60 degrees centigrade

Relative humidity

Maximum 75% at 40 degrees Celsius


 
 
  View All
  DPM-3AMA
  1/3 phase volt/amp
  DPM-VISA
  DPM-VIAA
  Three phase amp
  DPM-CDC 3.5 digit
  DPA-XSPA 3/4 Digit Amps
  DPA-XSPT 3/4 Digit Temp
 
DPA-XSPV 3/4 Digit Volt
 
DIG-NTOT 6 Dig Counter
 
DIG-NELP 6 Dig Timer
 
DIG-NRTC 6 Dig real Timer
  Housed Timers
  PDO
  PPE
  PPI
  PDFN
  Tel-A-Fare
  View All
  PFFC
  PFF1
  PFF2
  PFF3
  PFF4
  PWM
  PFR
  PFRP
  View All
  PLLP
  PVC
  PSPU1
  PSPU3
  PFP
  PCWD
  PPST
  PSA
  View All
  2 Digit Temp Controller
  3 Digit Temp Controller
  3 Digit H/Temp Controller
  3 Digit Thermo Control
  3 Digit Thermo Indicator
  2 Digit Indicator
  3 Digit Indicator
  2 Digit Temp Alarm
  Digital Panel Timer
Designed & maintained by
world-portalz.com
Site Designed and Maintained by  World-portalz.com