3.5
Digit Digital Panel meter
|
|
|
|
DPM-CDC |
| |
|
|
| You
can download a full spec sheet for this section.
This spec sheet is in adobe's acrobat reader format.
If you do not have this software please click
on the link below "download
acrobat reader". |
| |
|
|
|
|
 |
•
3 samples per second
• A.C. Measurement uses average algorithm
• Volt and Amp meters, AC or DC
• Remote monitoring
• Large LED Display
• Standard 96 X 48 X 75mm deep case
• +/-3 digits accuracy
• Maximum reading is 1999 counts
|
| |
For other panel meter
products select your preference in the menu on the
right >
|
| |
| The Microsolve Volts or Amp meter covers
all the requirements that you may have in a DC or A.C.
environment. This state of the art instrument uses a
dual slope analogue to digital converter technology
to bring you an inexpensive yet reliable and accurate
instrument. Designed using the minimum of components
for long term reliability, the measuring algorithm takes
approximately 3 readings per second, yet the display
is updated in such a manner that the reading is comfortable
on the eye. |
Single
Phase Volt / Amp Meters |
This instrument has been specifically
designed for voltage supply and current monitoring in
diverse applications such as motor panels, process control,
temperature control, in fact any application in which
the voltage or current needs to be monitored. |
|
The Amp meter instrument
has been designed for a maximum input of 5 Amps continuous.
Higher currents will require the use of a instrument
Class 1 type of current transformer with a secondary
ratio of 5 Amps or a resistive shunt. The display can
be easily adjusted to accommodate the ratio of the current
transformer or shunt by simply adjusting a 15 turn potentiometer
on the main board. Access to this potentiometer, requires
the user to remove the bezel and front plastic plate,
and with an insulated shaft mini screwdriver, rotate
the potentiometer until the desired current value is
displayed. We suggest that the current transformer ratio
be known at the time of ordering the instrument. |
monitoring
- DPM-VISA CARE MUST BE TAKEN DURING THIS PROCEDURE,
AS ALL POINTS OF THE INSTRUMENT WILL BE AT LINE POTENTIAL. |
|
|
| |
DPM-CDC |
There
are 2 types of instruments in this range, namely voltage
and current measurement. |
|
| The voltage instrument measures
a voltage values from 200 milli-volt up to a maximum
of 600V D.C. The input is set at the time of ordering.
The displayed value can either be the direct reading,
or another value, as required by the process being monitored.
An example would be a 0 – 10V input equivalent
to 0 – 300 RPM. The maximum reading displayed
will be 1999. |
|
The current instrument measures
values from 1 milli-Amp to 5 amps. The range is set
at the time of ordering. When using a resistive shunt,
the voltage of the shunt at the maximum current must
be supplied with the order. |
|
Specifications |
Aux Supply |
110V, 230V, 400V, 525V +/-20% of
nominal supply. |
Voltage monitoring |
DPM-CDCV/DPM-CACV |
Voltage range – single range
only |
100mV to 600V D.C./1000V A.C.
|
Current monitoring |
DPM-CDCA/DPM-CACA |
Current Input |
0 to 5 Amps. Span adjustable from
to
1999 via front Panel adjusted potentiometer.
|
Accuracy |
+/-3 digits across measurement
range |
Operating Temperature |
–5 to 60 degrees centigrade |
Relative humidity |
Maximum 75% at 40 degrees Celsius |
|